Daewoo Heavy Industries Mega 500-V — Transmission Error Condes (ZF)

S0607900C Page 20 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 7D S.C. to ground at engine derating device. • Cable is defective and is contacted to vehicle ground. • Engine derating device has an internal defect. • Connector pin is contacted to vehicle ground. Engine derating will be on until TCU power down even if fault vanishes (loose connection). OP-Mode: normal. Check cable from TCU to engine derating device. Check connectors from engine derating device to TCU. Check resistance 1) of engine derating device.

1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. (Only Mega 500-V) 7E S.C. to battery voltage at engine derating device. • Cable / connector is defective and is contacted to battery voltage. • Engine derating device has an internal defect. No reaction. OP-Mode: normal. Check cable from TCU to engine derating device. Check connectors from backup alarm device to TCU. Check resistance 1) of backup alarm device. Only Mega 500-V 7F O.C. at engine derating device. TCU detected a wrong voltage at output pin, that looks like a O.C. for this output pin. • Cable is defective and has no connection to TCU. • Engine derating device has an internal defect.

• Connector has no connection to TCU. No reaction. OP-Mode: normal. Check cable from TCU to engine derating device. Check connectors from engine derating device to TCU. Check resistance 1) of engine derating device. 1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. (Only Mega 500-V) 81 S.C. to battery voltage at clutch K4. The measured resistance value of valve is out of limit, voltage at K4 valve is too high. • Cable / connector is defective and has contact to battery voltage. • Cable / connector is defective and has contact to another regulator output of TCU. • Regulator has an internal defect. TCU shifts to neutral. OP-Mode: limp home.

If failure at another clutch is pending. TCU shifts to neutral. OP-Mode: TCU shut down. Check cable from TCU to gearbox. Check connectors from gearbox to TCU. Check regulator resistance. 1) Check internal wire harness of gearbox. 1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.