daewoo Mega 500-V — Transmission Error Condes (ZF)

S0607900C Page 22 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks 86 O.C. at clutch KV. The measured resistance value of valve is out of limit. • Cable / connector is defective and has no contact to TCU. • Regulator has an internal defect. TCU shifts to neutral. OP-Mode: limp home. If failure at another clutch is pending. TCU shifts to neutral. OP-Mode: TCU shut down. Check cable from TCU to gearbox. Check connectors from gearbox to TCU. Check regulator resistance. 1) Check internal wire harness of gearbox.

1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. 87 S.C. to battery voltage at clutch KR. The measured resistance value of valve is out of limit, voltage at KR valve is too high. • Cable / connector is defective and has contact to battery voltage. • Cable / connector is defective and has contact to another regulator output of TCU. • Regulator has an internal defect. TCU shifts to neutral. OP-Mode: limp home. If failure at another clutch is pending. TCU shifts to neutral. OP-Mode: TCU shut down. Check cable from TCU to gearbox. Check connectors from gearbox to TCU. Check regulator resistance. 1) Check internal wire harness of gearbox.

1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. 88 S.C. to ground at clutch KR. The measured resistance value of valve is out of limit, voltage at KR valve is too low. • Cable / connector is defective and has contact to vehicle ground. • Regulator has an internal defect. TCU shifts to neutral. OP-Mode: limp home. If failure at another clutch is pending. TCU shifts to neutral. OP-Mode: TCU shut down. Check cable from TCU to gearbox. Check connectors from gearbox to TCU. Check regulator resistance. 1) Check internal wire harness of gearbox. 1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. 89 O.C. at clutch KR.

The measured resistance value of valve is out of limit. • Cable / connector is defective and has no contact to TCU. • Regulator has an internal defect. TCU shifts to neutral. OP-Mode: limp home. If failure at another clutch is pending. TCU shifts to neutral. OP-Mode: TCU shut down. Check cable from TCU to gearbox. Check connectors from gearbox to TCU. Check regulator resistance. 1) Check internal wire harness of gearbox. 1) See “Measurement of Resistance at Actuator/sensors and Cable” on page 35. * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.