Daewoo Heavy Industries Mega 500-V — Transmission Error Condes (ZF)

S0607900C Page 29 Transmission Error Codes (ZF) Fault Code (hex) Meaning of the Fault Code (Possible reason for fault detection.) Reaction of the TCU Possible Steps to Repair Remarks D4 High power at battery. Measured voltage at power supply is higher than 32 V. Shift to neutral. OP-Mode: TCU shut down. Check power supply battery. Check cables from batteries to TCU. Check connectors from batteries to TCU. --------------- D5 Error at switch 1 for valve power supply VPS1. TCU switched on VPS1 and measured VPS1 is off or TCU switched off VPS1 and measured VPS1 is still on. • Cable or connectors are defect and are contacted to battery voltage.

• Cable or connectors are defect and are contacted to vehicle ground. • Permanent power supply KL30 missing. • TCU has an internal defect. Shift to neutral. OP-Mode: TCU shut down. Check fuse. Check cables from gearbox to TCU. Check connectors from gearbox to TCU. Replace TCU. --------------- D6 Error at switch 2 for valve power supply VPS2. TCU switched on VPS2 and measured VPS2 is off or TCU switched off VPS2 and measured VPS2 is still on. • Cable or connectors are defect and are contacted to battery voltage. • Cable or connectors are defect and are contacted to vehicle ground. • Permanent power supply KL30 missing. • TCU has an internal defect. Shift to neutral. OP-Mode: TCU shut down.

Check fuse. Check cables from gearbox to TCU. Check connectors from gearbox to TCU. Replace TCU. --------------- * Only Mega 400-III PLUS ** Only Series "V" Gray shaded boxes are error codes for other applications. They are only given for general reference purposes.