Return to Master Table of Contents ACCUMULATOR CHARGING WARNING! In the event of a diaphragm or upper valve failure, or any type of accident or handling fault, the upper chamber of the accumulator could at some point require re-pressurization. Depending upon the specific procedures and safety precautions recommended for the type and model accumulator that has been installed on your machine, a specialized adapter and/or filling tool may be required to perform the procedure. Consult your dealer or Daewoo After Sales Service for more information and follow recommended procedures carefully. All accumulators may contain gas held under high pressure.
Careless handling or improper disassembly could release explosive stored energy, resulting in an accident or injury. NOTE: Some machines use 320 cc (19.53 in 3 ) Bosch Accumulators with a nitrogen precharge (P1) pressure of 15 kg/cm 2 (213 psi). Always verify pre-charge pressure by checking the manufacturer’s data label on the exterior of the accumulator. CHARGING THE ACCUMULATOR WITH NITROGEN 1. Remove the protective cap (10, Figure 3) and the protective plug (11) from the accumulator (6). Figure 3 S0703000 Page 7 Accumulator