Daewoo Heavy Industries Mega 500-V — Main Pump (Denison T6DMY Series)

S0708460K Page 16 Main Pump (Denison T6DMY Series) Problem Possible Cause Remedy Pump making noise, Pump intake partially blocked. Service intake strainers. Check fluid condition and, if necessary, drain and flush system. Refill with clean fluid. Air leaks at intake or shaft seal. (Oil in reservoir would probably be foamy). Check inlet connections and seal to determine where air is being drawn in. Tighten any loose connections and replace seal if necessary. See that fluid in reservoir is above intake pipe opening. Pump drive speed too slow or too fast. Operate pump at recommended speed. Coupling misalignment. Check if shaft seal bearing or other parts have been damaged.

Replace any damaged parts. Realign coupled shafts.