REASSEMBLY NOTE: Coat all parts except seals and back-up rings with clean hydraulic fluid to facilitate assembly and provide initial lubrication. Use small amounts of petroleum jelly to hold O- rings in place during assembly. IMPORTANT During handling and shipping of precision machined cartridge parts, it is possible to raise burrs on sharp edges. All sharp edges on parts of a new cartridge kit should be stoned before installation. NOTE: To reverse direction of a new cartridge kit, simply reverse location of inlet and outlet support plates, and realign cartridge with cover. See steps 1H through 1J. 1.
Cartridge reassembly - The direction of rotation is as viewed from shaft end, right-hand rotation is clockwise; left-hand, counterclockwise. NOTE: If locating pins were removed from inlet support plate, install new pins with locking flutes within inlet support plate. Drive new pins into support plate, with a soft tip hammer. A. Place inlet and outlet support plates on a flat surface as shown in Figure 20. Install seal packs into cavities with seal retainer surface up. (O- rings facing downward into cavities.) B. Place a flex side plate over each of support plates with bronze wear surface facing up. Align scribe marks to make sure correct flex side plate is used with correct support plate. NOTE:
Flex side plates develop a wear pattern with rotor and vanes and should not be interchanged. Figure 20 C. For right-hand rotation units, set rotor on flat wooden board with arrow pointing right. (For left-hand rotation arrow should point left.) Assemble vanes and inserts into rotor in reverse order. (See Figure 21.) Make sure sharp chamfer edge of each vane leads in direction of rotation. All vanes must move freely in rotor slots with no evidence of bind. D. Assemble cam ring over rotor and vanes with arrow pointing in same direction as rotor. Lubricate top surface of rotor and vanes liberally with system fluid. Figure 21 S0708460K Page 22 Main Pump (Denison T6DMY Series)