Daewoo Heavy Industries Mega 500-V — Main Pump (Denison T6DMY Series)

I. Install cover over cartridge. Tap lightly on cover with your hand until each part centers. Remove cover gently so as not to disturb alignment. Torque socket head screws to torque noted on Figure 8, and recheck kit alignment with cover. Repeat until cartridge kit is aligned. (See Figure 24.) J. Check rotor for bind by inserting index finger through shaft opening of inlet support plate. Hold cartridge kit in a horizontal shaft position and lift rotor with finger. Rotor should move freely back and forth within cartridge. If rotor binds, open kit, clean and stone all possible areas of bind, then reassemble using aforementioned procedure. Rotor MUST move freely within cartridge when assembled.

2. Basic pump reassembly - Clamp body in a vise or place on 2x4 wooden blocks to facilitate assembly. (See Figure 10 and Figure 11.) Figure 24 A. Lubricate primary shaft seal with petroleum jelly and place in position within body, garter spring up. See Figure 6 for seal arrangements. B. Use seal installation tool shown in Figure 9 to prevent damage to seal. Press seal into body until it bottoms out. NOTE: Two shaft seal arrangements are available in VQ pump series. See Figure 6 and Figure 7. C. Lubricate secondary seal with petroleum jelly and place seal in position against shaft end of body. See Figure 7. Use a small hardwood block to drive seal evenly into body.

Installation is complete when seal face is flush with front of body. DO NOT drive seal past flush as it can block body drain opening. NOTE: If shaft bearing was defective, install a new bearing as follows: D. Press shaft into new bearing with an arbor press while supporting bearing inner race. Refer to Figure 6 and Figure 8 for correct location of bearing on shaft. Install a small snap ring behind bearing. E. Place bearing spacer washer over shaft, against front of bearing. Use a "bullet" over shaft end to prevent damage to seal(s). Lubricate "bullet" with petroleum jelly and carefully push shaft through seals until bearing and spacer is in location within body.

Install large spirolox ring into body snap ring groove behind bearing. F. Install square sealing ring into body. See Figure 2 and Figure 8 (sectional view) for location. G. Install O-ring and back-up ring on cartridge, outlet support plate hub. See Figure 8 for location. H. Carefully install cartridge into body so one of the chamfers on cam ring aligns with cover inlet port. I. Lubricate and install large cover to body O-ring in place. S0708460K Page 24 Main Pump (Denison T6DMY Series)