Daewoo Heavy Industries Mega 500-V — Flow Amplifier (Danfoss)

SPECIFICATIONS S0709665K Page 5 Flow Amplifier (Danfoss) Reference Number Description 1 O-ring 2 O-ring 3 O-ring 4 O-ring 5 Washer 6 Washer 7 O-ring 8 O-ring 9 Housing 10 Check Valve 11 Screw 12 Washer; Spring 13 Screw 14 Washer; Spring 15 End Cover 16 End Cover 17 Relief Valve 20 Plug 21 Shock and Suction Valve Reference Number Description 22 Stopper 23 Stopper 24 Guide; Spring 25 Screw; Drive 26 Plate; Name 27 Orifice 28 Spring 29 Spring 30 Spring 31 Plug 32 Washer 34 Orifice 35 Orifice 36 Orifice 37 Throttle Check Valve 38 Plug 40 Spring 41 Spring Flow Amplifier Specification Type Contains a directional valve, an amplification stage, a priority valve, a pilot pressure relief valve and suction valve.

Amplification Factor 8 Control Pressure 10.50 kg/cm2 (149.35 psi) LS Relief Valve Setting 185.0 ±5.0 bar (2,683.24 ±72.52 psi)) Max. Oil Flow to Steering 125.0 l/min. (33.0 U.S. gpm)