daewoo Mega 500-V — Flow Amplifier (Danfoss)

S0709665K Page 8 Flow Amplifier (Danfoss) STEERING SYSTEM WITH OSQA/B AND OSPBX-LS Problem Possible Causes Remedies Amplification too large Dirty, leaky or missing check valve (1). Clean or replace check valve. Piston (2) sticks in the open position. Clean and check that the piston moves easily. Amplification too small Piston (2) sticks in the closed position. Clean and check that the piston moves easily. Piston (2) incorrectly installed (only OSQA/B-5). Rotate the piston 180˚ on its axle. Heavy turning of steering wheel and slow increase of amplification Dirty orifices (3) in directional valve. Clean or replace orifice. Dirty orifices (4) in the combi-valve spool. Clean or replace orifice.

Dirty orifices (5) in housing. Clean or replace orifice. Dirty orifices (6) in LS-port. Clean or replace orifice. Dirty orifices in throttle/check valve (7) in PP-port. Clean or replace throttle/check valve. No end stop in one or both directions. One or both shock valves (8) set too low. Setting takes a long time without special equipment. Contact the nearest service shop. One or both anti-cavitation valves (9) leaky, or sticks. Clean or replace completely shock/anti-cavitation valve(s). Missing end-stop plate(s) pos. 10 for directional valve. Fit end-stop plates. "Hard" point when starting to turn the steering wheel Air in LS and/or PP pipes. Bleed pipes.

Spring force in the built in priority valve too weak (11). Replace spring with one which is more powerful. (There are three sizes: 4, 7 and 10 bar). Orifices in respectively LS-(6) or PP-(7) ports blocked. Take out and clean orifices. No pressure build-up LS-pressure limitation valve (12) adjusted too low. Remove plug and set to specified pressure. Spool and sleeve in OSPBX steering unit put together incorrectly. Take out spool set and turn the inner spool 180˚ in the outer sleeve. (See service manual) Emergency control ball in steering unit missing. Install new ball. Pump does not run or is defective. Repair or replace pump.