daewoo Mega 500-V — Flow Amplifier (Danfoss)

2. Assemble check valve. A. Install ball, spring and plug. B. Tightening torque: 0.5 ±1 daNm. (45 ±90 in lb). Figure 74 3. Assembly of amplifier spool. A. Install orifice in plug. Tightening torque: 0.5 ±1 daNm. (45 ±90 in lb). Figure 75 B. Install check valve. Tightening torque: 2 ±0.3 daNm. (175 ±25 in lb). NOTE: Avoid damaging spool surface. Remember O-ring. Figure 76 S0709665K Page 33 Flow Amplifier (Danfoss)