E. Install throttle check valve in PP- connection. F. Tighten torque: 1 ±0.3 daNm. (90 ±25 in lb.). 7. Comments on flow amplifiers with internal PP: A. 1/4 BSP.F in PP-connection: Install washer and plug. Tightening torque 4 ±0.3 daNm (355 ±25 in lb). B. 7/116 - 20 UNF in PP-connection: Install O-ring and plug. Tightening torque: 1.5 ±0.5 daNm (135 ±45 in lb). Figure 89 8. Installation of shock valves. A. Guide shock valve in and secure it by hand. Remember O-ring. Figure 90 9. Assembly of pressure relief valve. A. Guide adjustment screw, spring and cone up into cartridge. Figure 91 S0709665K Page 38 Flow Amplifier (Danfoss)