daewoo Mega 500-V — Electrical System

Return to Master Table of Contents ENGINE STOP AND DERATING SYSTEM OPERATION IN ENGINE STOP MODE The engine stop is achieved by the "open" or "closed" operation of the fuel shutoff valve in fuel pump with limited speed governor and duel lever control. When the starter switch (5) is in the "ON" position, the fuel shutoff valve is opened due to the current flowing from the "BR" terminal of the starter switch (5) the fuel shutoff valve (7) and fuel is supplied to the cylinder. As a result the engine is being started.

When the starter switch (5) is in the "OFF" position during the engine running, because the current is not applied to the fuel shutoff valve (7), it is closed and fuel is not supplied to the cylinder. As a result the engine is stopped. AHS0060L Figure 7 ENGINE STOP CIRUIT S0802190K Page 12 Electrical System Reference Number Description 1 Battery 2 Battery Relay 3 Fusible Link 4 Circuit Breaker Reference Number Description 5 Starter Switch 6 Fuse Box 7 Fuel Shot Off Valve 8 Diode