Return to Master Table of Contents TROUBLESHOOTING On some pumps the ON-OFF switch is installed separately at a remote location. A thermal limiter, built into the motor, will automatically shut off power if motor is overheating to protect it from damage. NOTE: OPEN TEMP: 150 ±5°C (302 ±41°F). After circuit is automatically shut off due to overheating the pump will stop running. When temperature drops below 143˚C (289˚F) the circuit will reactivate allowing the pump to restart. Figure 3 WITH TOGGLE SWITCH Figure 4 WITHOUT TOGGLE SWITCH Check resistance at connectors "A." If reading is zero, or very close to zero, the motor is bad and must be replaced.
On units equipped with a toggle switch, check the resistance through the toggle switch, while the switch is in the "ON" position. If continuity is not present, the switch is bad. Be sure to check resistance through the motor. REPLACEMENT OF ROTOR AND VANE If dirt or other foreign materials enter pump during operation, it can become lodged between the rotor and/or vanes and generate heat which can cause pump damage. Remove the pump cover and check the rotor and vane. If any pump parts or components become lost, damaged or inoperable, immediately replace them with a new ones. Figure 5 WITHOUT TOGGLE SWITCH S0405500 Page 4 Fuel Transfer Pump