Isuzu 727 N SERIES (4HK1 Engine) — Quick On Start (QOS) System does Not Operate

1A-142 Engine Control System Quick On Start (QOS) System does Not Operate Preliminary Checks Road test the vehicle with a Digital Multimeter (5- 8840-0366-0) connected to a suspected circuit. In case of a malfunction, abnormal voltage indicates the presence of a fault in the circuit being checked. Use a scan tool to help detect intermittent conditions. The scan tools have several features that can be used to locate an intermittent condition. Use the following feature for find intermittent faults: Before using this section, perform the ’’On-Board Diagnostic (OBD) System Check’’ and verify all of the following items: The ECM and CHECK ENGINE Lamp (MIL) are operating correctly.

There are no DTCs stored. Tech 2 data is within normal operating range. Verify the customer complaint and locate the correct symptom in the table of contents. Perform the procedure included in the symptom diagnosis chart. The check for loss of DTC memory, disconnect the intake air pressure sensor and idle the engine until the CHECK ENGINE Lamp (MIL) comes on. DTC32 should be stored and kept in memory when the starter switch is turned “OFF”. If not, the ECM is faulty. When this test is completed, make sure that you clear the DTC32 from memory. A CHECK ENGINE Lamp (MIL) with no stored DTC may be caused by the following: CHECK ENGINE Lamp (MIL) wire to ECM shorted to ground. Poor ECM grounds.

Check for improper installation of electrical options such as lights, cellular phones, etc. Visual/Physical Check Several of the symptom procedures call for a careful visual/physical check. This can lead to correcting a problem without further checks and can save valuable time. This check should include the following items: ECM grounds for cleanliness, tightness and proper location. Wiring for proper connections, pinches and cuts. Check if the fuse has blown. Check if the glow plug is normal.

If DTC is not confirmed, snap-shot the Tech 2 data list, so that approximate faulty location can be estimated according to the follow-up performance or validity of numeric values, or identification of fixed values. 1. If a systematic error is recognized in numeric values, fundamental accuracy of instruments such as sensors will be faulty (for example, variations in sensor resistance value). 2. If a random error is recognized in numeric values, in general it will be caused by electrical (applied voltage) or mechanical troubles or noise. 3. If numeric values are fixed to high or low (fixed value error), the open wiring or short will occur in the circuits of instruments such as sensors.

Intermittents IMPORTANT: An intermittent problem may or may not turn on the CHECK ENGINE Lamp (MIL) or store a DTC. Do not use the Diagnostic Trouble Code (DTC) charts for intermittent problems. The fault must be present to locate the problems. Most intermittent problems are caused by faulty electrical connections or wiring. Perform a careful visual/physical check for the following conditions: Poor mating of the connector halves of a pin not fully seated in the connector (backed out). Improperly formed or damaged pin. All connector pin in the problem circuit should be carefully checked for proper contact tension. Poor pin-to-wire connection.

This requires removing the pin from the connector body to check. Further, you may be able to detect a trouble by disconnecting the connectors of related sensors and checking variations in numeric values or indication of Tech 2. The part concerned is normal if a variation is recognized when its connector is disconnected, or it is faulty if no variation is recognized. Related Sensors: Glow relay, Glow plug Step Action Value(s) Yes No 1 Was the “On-board Diagnostic (OBD) System Check” performed? — Go to Step 2 Go to “OBD System Check”