Komatsu — (3) Waste gate valve adjustment procedure

8. Turbocharger (for 4TNE106T) (3.1) Method for checking the waste gate valve opening pressure and lift @ Equipment Prepare the equipment shown in the figure below. @ Measuring instruments and devices Dial gage Capable of measuring 0 to 10 mm (A flat head type is recommendable.) Pressure regulating valve Allowing gradual adjustment in a range between 0 and 2 kgf/cm2 (0.196 Mpa) Manometer Mercury column or electrical type (capable of measuring 0 to 1500 mmHg) Pressure reducing valve Used for suppressing the air supply pressure at 5 kgf /cm* (0.49 Mpa) or less. 1 Pressure gage 1 Bourdon tube pressure gage (0 to 10 kgf/cm* (0.98 Mpa)) I Waste gate actuator \ Waste gate valve pre,?;.

redz;;vegulating valve Manometer [Note] PC (controller pressure) varies with the set output in a range between 600 and 750 mmHg. 0 a. Check method Set the manometer control pressure (PC) applied to the waste gate actuator to 0 and set the dial gage to the zero point. Gradually open the pressure regulating valve and measure the PC value when the actua- tor rod is operated by 2 mm. For the hysteresis, let the rod move to 3 mm first. The gradually close the pressure regulating valve, measure the pressure when the rod is moved to 2 mm and obtain the difference from the pressure measured in b. above. b. C. 0 . Precautions . The piping and joints shall completely be free from leak.

Fix the turbocharger and dial gage securely. If an electric manometer is used, it shall have sufficient precision. Set the dial gage on the extension line of the actuator rod. . . . Even when an electric manometer is used, use of a mercury column type manometer in combination is recommended for calibration and daily check. . The speed for increasing/decreasing PC by means of the pressure regulating valve shall be very slow near the measuring point. If the 2 mm position is exceeded, restart from the . beginning. Do not apply over 5 kgf/cm2 (0.49 MPa) to the actuator. (3.2) Waste gate actuator leak test Apply 1.2 kgf/cm2 (0.12 Mpa) to the actuator and hold the state for 1 minute.

The actuator is good if the pressure then is 1 .l kgf/cm2 (0.11 MPa) or above. a-7