Komatsu — (4) Magnetic switch continuity test

9. Starting Motor W If the brush does not move smoothly, inspect the brush holder for bending and the brush holder sliding surface for dirt. Repair or clean as needed. Check the continuity between the insulated brush holder (positive (+)) and the brush holder Check of brush movement c) base (negative (-)). If they are electrically continuous, replace since the holder is grounded. (Checking insulation of brush holder) (4) Magnetic switch continuity test Continuity test Measurement point Normal Abnormal (cause) Shunt coil Between C and ground Yes None (open circuit) Series coil CandM None Yes (short-circuiting) Replace if needed. (Magnetic switch connection diagram) 9-26