Komatsu — (2) Rotor

10. Alternator 10.1.5 Inspection and overhaul (1) Diode The diode makes the current flow only in the direction shown in Fig. 8. Check elec- u V w @ C 0 0 diode trical continuity between two terminals (for tester as shown in Fig. 9 and, if they are continuity, the diode is acceptable. If not, example, terminals BAT and U) using a AT ceptable if two terminals are not continuity when the tester is connected in the re- the diode is damaged. The diode is ac- T E diode verse manner. The diode is damaged if they are continuity. If even a single diode is faulty as a result of Fig. 8 the above measurements, replace the en- tire diode assembly.

Tester leads Tester leads X@ e Q / - / co?Euity I I Q 1 coKuity / - I c3 I Continuity I - I Checking (+) diode Checking (-) diode Note: Never use a high-voltage insulation ohmmeter Tester 1 such as a megger for testing. Otherwise, the diode may be damaged. (2) Rotor (a) Wear limit for slip spring Measure the outside diameter of the slip Fig. 9 spring. If wear exceeding 1 mm from the tor assembly. standard size is measured, replace the ro- Standard: 27 mm, Wear limit: 26 mm (b) Check of slip ring surface and free from contamination by oil, etc. If Check that the slip ring surface is smooth the surface is rough, polish using #500 to #600 emery cloth. If it is dirty, clean using alcohol. Fig.

10 1 o-7