Komatsu — (5) Check of IC regulator

IO. Alternator @ Measure voltage at V2 (voltage across terminals F and E) while gradually increasing the resistance 0 V. Check that there is a point of the variable resistor starting from where the V2 voltage reaches 2.0 V or less of the Vl value of BAT1 measured in @ above. If no change occurs, the regulator is faulty. So, replace it with a new one. @ Measure voltage at V4 (voltage across the intermediate tap of the variable resistor and E-terminal), with variable resistor Rv being fixed. If the measured value is within the specified range, the regulator is acceptable. If not, the regulator is faulty. So, replace it with a new one. 10-10