EPA04 MBE 4000 ENGINE OPERATOR'S GUIDE Monitoring Engine Operation While the engine is operating, monitor the battery charge indicator light, the oil pressure and avoid excessive idling. FIRE To avoid injury from fire, keep all potential ignition sources away from diesel fuel, including open flames, sparks, and electrical resistance heating elements. Do not smoke when refueling. Battery Charge The battery charge indicator light (see Figure 14) must go out once the engine starts. 3. Do a load test on the batteries. Charge or replace the batteries as needed. 4. If necessary, visit the nearest authorized dealer to have the alternator voltage and output checked.
Oil Pressure When the engine has reached its normal operating temperature, the engine oil pressure must not drop below the following values: Figure 14 Battery Charge Indicator Light If the indicator light comes on while the engine is running, do the following: 36 psi (250 kPa) at rated speed 7 psi (50 kPa) at idling speed 1. Shut down the engine. If oil pressure drops below these values, stop the engine and determine the cause. 2. Check the poly-V belt for tightness. All information subject to change without notice. (Rev. 04/08) 27 DDC-SVC-MAN-0056 04/08 Copyright © 2008 DETROIT DIESEL CORPORATION