EPA04 MBE 4000 ENGINE OPERATOR'S GUIDE Emergency Running Mode Stop Engine Override Option The engine is equipped with the electronic engine control system, which monitors the engine as it is running. The Stop Engine Override Option is used for a momentary override. The DDEC-ECU will record the number of times the override is activated after a fault occurs. As soon as a fault is detected, it is evaluated and one of the following measures is initiated. Momentary Override A Stop Engine Override (SEO) switch is used to override the shutdown sequence (see Figure).
This override resets the 60 second (30 seconds for oil pressure) shutdown timer, restoring power to the level when the Red Stop Lamp (RSL) was illuminated. The switch must be recycled after five seconds to obtain a subsequent override. NOTICE: To prevent possible serious engine damage, have any faults corrected without delay by an authorized dealer. In conjunction with any dashboard or instrument panel display, the code for the electronic control unit reporting the fault can be read immediately on the display. Complete fault codes are transmitted and can be read using minidiag2, the Nexiq DDR or DDDL PC software.
If the fault is serious enough to impair normal operation, the electronic engine system switches over to emergency running mode. When in emergency running mode, the engine operates at a constant 1300 rpm. This allows you to move the vehicle to a service location. Figure 15 Typical SEO Switch and Warning Lamps NOTE: The operator has the responsibility to take action to avoid engine damage. For fault codes and their meanings, see the vehicle service manual. All information subject to change without notice. (Rev. 04/08) 29 DDC-SVC-MAN-0056 04/08 Copyright © 2008 DETROIT DIESEL CORPORATION