EPA04 MBE 4000 ENGINE OPERATOR'S GUIDE De-ionized water the requirements of the Truck Maintenance Council (TMC). Coolant specifications are listed in Table 2. NOTICE: In some areas, tap water can contain high levels of dissolved chlorides, sulfates, magnesium, and calcium, causing scale deposits, sludge deposits and/or corrosion. These deposits can damage the coolant pump and allow the engine to overheat. Coolant Concentration When topping off the cooling system after a drop in the coolant level, the concentration of corrosion-inhibiting antifreeze in the coolant must be 50 percent by volume. This affords protection down to a temperature of –37°C (–34°F).
The cooling mixing ratio is listed in Table 3. Coolant Specifications NOTE: If the concentration is too low, there is risk of corrosion/cavitation in the cooling system. To avoid damage to the cooling system, use only an approved corrosion-inhibiting antifreeze. Approved antifreeze must be fully-formulated and comply with Table 2 Coolant Specifications Table 3 Coolant Mixing Ratio All information subject to change without notice. (Rev.
04/08) 51 DDC-SVC-MAN-0056 04/08 Copyright © 2008 DETROIT DIESEL CORPORATION Type of Coolant Requirement Fully-Formulated Ethylene Glycol TMC RP-329 Type "A" Water plus Corrosion Inhibitors Temperature Must Not Fall Below 0°C (32°F) Antifreeze Protection Down to °C (°F) Water % by Volume Corrosion - Inhibiting Antifreeze % by Volume –37 (–34) 50 50 –52 (–62) 40 The cooling mix ratio is Max. 60