Komatsu — OTHER TROUBLE

. OPERATION TROUBLESHOOTING 3 - 132 ENGINE ( ): Always contact your Komatsu distributor when dealing with these it ems. In cases of problems or causes which are not listed below, contact your Komatsu distributor for repairs.

Problem Main causes Remedy Engine oil pressure caution lamp lights up Low coolant level, leakage of water Defective fan pump motor Dirt or scale accumulated in cooling system Clogged radiator fin or damaged fin Defective thermostat Loose radiator filler cap (high Engine coolant temperature gauge is in white range Defective thermostat ( Replace thermostat) Engine does not start when starting motor is turned Lack of fuel Air in fuel system No fuel in fuel filter Defective injection pump or nozzle Starting motor cranks engine too slowly Starting motor does not turn Preheating pilot lamp does not Add fuel, see CHECK BEFORE STARTING Repair place where air is sucked in Fuel filter with fuel.

See EVERY 500 HOURS SERVICE ( Replace pump or nozzle) See ELECTRICAL SYSTEM See ELECTRICAL SYSTEM See ELECTRICAL SYSTEM Exhaust gas is white or blue Too much oil in oil pan Add oil to specified level, see CHECK BEFORE STARTING Exhaust gas occasionally turns black Combustion noise occasionally makes breathing sound Defective nozzle ( Replace nozzle)