Isuzu — Isuzu N Series Training Manual

Caution: 1. For vehicles with 12 V and 24 V, this leveling input voltage is 12 V. 2. Input to SIGNAL must be less than 65% of the in- put voltage to positive terminal. 1 2 3 SIGNAL − + Input signal voltage ratio for SIGNAL when the volt- age difference between posi- tive and nega- tive is specified as 100% − + HEAD LAMP POSITION Position 0 10.0% (1.2 V) 0 V 12 V Position 1 23.4% (2.8 V) 0 V 12 V Position 2 36.7% (4.4 V) 0 V 12 V Position 3 50.0% (6.0 V) 0 V 12 V Position 4 63.4% (7.6 V) 0 V 12 V