Backup Light Bulb Removal Preparation: Disconnect the battery ground cable. 1. Lens 2. Bulb N8A0196E Removal Preparation: Disconnect the battery ground cable. 1. Backup Light Switch 1) Disconnect the connectors. 2) Remove the switch by turning it counterclock- wise. Installation 1. Backup Light Switch Apply liquid gasket to the screw portion of the switch to prevent oil leak. N8A0195E Installation To install, follow the removal steps in the reverse order. Backup Light Switch Inspection Backup Buzzer 1. With the switch installed to the transmission, check the continuity between the terminals of the switch connectors.

When the continuity is found between the terminals only with the switch shifted to the reverse position, the switch is normal. 2. When the result of the above inspection is found abnormal, remove the switch from the transmis- sion and conduct a test on the switch alone. If the continuity appears between the connector terminals when the ball of the switch is released, the switch is normal. (When the ball is pushed, the continuity disappears.) 3. If there is no continuity with the switch installed to the transmission, even though the switch is found to be normal, then adjust the stroke of the switch by changing the thickness of the switch gasket.

Inspection Apply battery voltage to the backup buzzer connector to check the buzzer sound. Repair or replace the buzzer when the result of inspec- tion is found abnormal. N8A0197E