3. Coolant Temperature Gauge 3-1. Coolant Temperature Gauge Needle Does Not Move IS THE CONNECTOR OF THE THERMO UNIT CONNECTED SECURELY? CONNECT THE CONNECTOR SECURELY REPLACE THE THERMO UNIT REPAIR A POOR CONNECTION AT THE CONNECTOR REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN OPEN CIRCUIT IN THE CIRCUIT REPLACE THE PRINTED CIRCUIT BOARD CHECK THE COOLANT TEMPERATURE GAUGE AND REPLACE IT WITH A CORRECT ONE IF NECESSARY N8A0308E Y ES N O • • • DISCONNECT THE CONNECTOR OF THE THERMO UNIT CONNECT A 3.4W BULB BETWEEN THE HARNESS SIDE CONNECTOR 1 E-7 AND THE GROUND OF THE THERMO UNIT WHEN THE STARTER SW IS TURNED ON, DOES THE TEMPERATURE GAUGE NEEDLE MOVE ABOUT 10 SECONDS AFTER THAT?

Y ES N O • IS THE THERMO UNIT NORMAL? • IS THE CIRCUIT BETWEEN THE TEMPERATURE GAUGE AND THE THERMO UNIT NORMAL? Y ES N O Y ES N O • IS THERE A BROKEN WIRE IN THE PRINTED CIRCUIT OF THE METER ASSEMBLY? Y ES N O