Isuzu — Isuzu N Series Training Manual

Brake Fluid Switch Inspection 1. Confirm there is continuity between the switch con- nector terminals when the brake fluid in the tank is between 60 — 75 cc level. 2. Turn the switch on, disconnect the brake fluid switch connector and connect the harness side connector terminals. Then confirm that brake warning light turns on. If found defective, replace the tank, or repair a poor connection or an open circuit between the connec- tor terminals. 1 2 N8A0358E Legend 1. Meter Assembly 2. Vacuum Warning Buzzer Installation To install, follow the removal steps in the reverse order. Water Sedimenter Switch Inspection 1.

When the float in the water sedimenter is above the drain warning level, confirm if there is continuity be- tween the switch connector terminals. 2. Turn the starter switch on, disconnect the water sedimenter connector and connect the harness side connector terminals. Then confirm that the sedimenter warning light turns on. If found defective, replace the switch or repair a poor connection or an open circuit between the connector terminals. N8A0360E Removal Preparation: Disconnect the battery ground cable. 1. Instrument Panel Assembly Refer to “INSTRUMENT PANEL” of section 2. 2. Brake Fluid Tank (Brake Fluid Switch) 1) Disconnect the switch connector. 2) Remove four fixing nuts.

3) Drain brake fluid in the tank. 4) Disconnect the tubes. Caution: Be very careful not to allow the brake fluid to come in contact with painted surfaces or resin parts surfaces. N8A0359E