Isuzu — Isuzu N Series Training Manual

Guard Replacement 4. Adjust so that the booster clevis position dimension (the distance to the center of the clevis hole from the surface of the flange for attachment to the ve- hicle) is 109 ± 1 mm (4.29 ± 0.04 in), and tighten the lock nut with the prescribed torque. When tighten- ing the lock nut, be careful not to deform the clevis. Removal 1. Remove hydraulic booster assembly. Refer to “Removal” of Hydraulic Booster in this section. 2. Secure the hydro boost assembly to the jig using the four stud bolts on the surface of the flange for attachment to the vehicle. 3.

Being careful not to exert any off-center load on the operating rod, loosen the lock nut and remove the clevis and lock nut. 4. Remove the guard from the cover boss anchoring groove and from the operating rod anchoring groove, and pull it out. Tighten: Lock nut to 20 N m (2.0 kg m / 14 lb ft) 5. Attach the hydro boost assembly to the vehicle. Refer to “Installation” of Hydraulic Booster in this section. Installation 1. With a dry cloth, clean well the cover boss anchor- ing groove and the operating rod anchoring groove, and verify that no foreign matter is present. 2.

Insert from the large diameter hole side of the guard end-face into the operating rod outside di- ameter part, assemble the small diameter hole part of the guard end-face into the anchoring groove of the operating rod, then assemble the large diame- ter hole part securely into the anchoring groove of the boss of the cover. 3. Screw the lock nut and then the clevis onto the op- erating rod. N5A0010E Legend 1. Accumulator 2. Stud bolt 3. Cover boss 4. Lock nut 5. Clevis 6. Operating rod 7. Guard 8. Flange