Isuzu — Isuzu N Series Training Manual

Item Service Standard Service Limit Starter Load Characteristics Terminal Voltage V Load Current A Torque N⋅m (kg⋅m / lb⋅ft) Speed rpm 18.55 250 14.2 (1.45 / 10.5) or more 860 Terminal ACC B ON ST B1 P1 P2 W W LOCK ACC ON START N6A1414E Preheating system (QOSII) Time required for the sec glow indicator to light up 3.5 After the key switch is turned to ON position without engine turned. Time required for the sec source voltage to be supplied to the glow plug 18 After the key switch is turned to ON position without engine turned. Glow Relay Coil Resis- Ω tance Nominal resistance 51.5 Thermo Switch Operat- °C (°F) ing Temperature OFF → ON: 7 — 13 (44.6 — 55.4) ON → OFF:

Less 3 (37.4) Glow Plug Continuity If no continuity exists, must be replaced. Terminal ACC B ON ST B1 P1 P2 W W LOCK ACC ON START