Isuzu — Isuzu N Series Training Manual

THERMOSTAT Component N6A0805E Legend 1. Radiator upper hose 3. Thermostat 2. Water outlet pipe Removal Inspection Preparation Disconnect battery ground cable Make the necessary adjustments, repairs, and part re- placements if excessive wear or damage is discovered during inspection. Operating Test 1. Completely submerge the thermostat in water. 2. Heat the water. Stir the water constantly to avoid direct heat being applied to the thermostat. 3. Check the valve initial opening temperature. Drain coolant 1. Radiator Upper Hose Disconnect radiator upper hose from radiator. 2. Water Outlet Pipe Remove mounting bolt and remove outlet pipe to- gether with radiator upper hose. 3. Thermostat