2. Remove the radiator valve and check a negative pressure valve as the center of the valve seat side. If the negative pressure valve does not work smoothly, clean or replace the radiator valve. Tighten: Radiator valve fixing to 6 N m (0.6 kg m / 4 lb ft) 3. Conduct cooling system leakage check after rein- stalling the radiator valve. Cooling System Leakage Check 1. Clog up the reservoir tank hose carefully and check the cooling system for leakage with a radiator cap tester by applying an air pressure of 196 kPa (2 kg/ cm 2 /28 psi) from filler neck to inside the radiator. 2.
As the radiator upper tank is provided with a valve, the pressure fails to rise higher than the valve opening pressure unless the hose is clogged up. N6A0810E 1. Radiator Upper Hose 2. Radiator Lower Hose Disconnect upper hose and lower hose from the ra- diator. 3. Coolant Reserve Tank Hose 4. Fan Guide 5. Radiator 1) Remove upward the radiator assembly with hose, taking care not to damage the radiator core by fan blade. N6A0812E Radiator Core 1. Deformed radiator fins could reduce radiation ef- fects, resulting in overheat. Straighten the fins. In such a case, take care not to damage the fin roots. 2. Remove dust and other foreign materials.
Flushing the Radiator Wash the inside of radiator and the coolant passage with water and neutral detergent. Remove all scales and rust. Installation N6A0811E 1. Radiator With due attention paid not to damage the radiator core by the fan blades, install the both brackets of the radiator to the brackets on the frame as shown in the illustration. Inspection Radiator Valve Check 1. Apply air pressure from filler neck using radiator cap tester and check the opening pressure of radi- ator valve. If the valve opening pressure is out of the standard value range, replace with a new radi- ator valve. Radiator Valve Opening Pressure kPa (kg/cm 2 /psi) 93 — 123 (0.95 — 1.25/13.5 — 17.8)