Opening Pressure Adjustment 1. Clamp the injection nozzle holder (1) in a vise (2). 2. Use a wrench to remove the injection nozzle retain- ing nut (3). 9. Attach the injection nozzle holder to the injection nozzle tester. 10. Apply pressure to the nozzle tester to check that the injection nozzle opens at the specified pres- sure. If the injection nozzle does not open at the speci- fied pressure, install or remove the appropriate number or adjusting shims to adjust it. Removing or installing one shim will increase or decrease the nozzle opening pressure approxi- mately 370 kPa (3.77 kg/cm 2 / 53.6 psi). Spray Pattern Check the spray condition. Refer to the illustration.
Spray Condition N6A0855E Correct (1) 3. Remove the injection nozzle holder from the vise. 4. Remove the injection nozzle (4), the spacer (5), the spring seat (6) the spring (7) and the adjusting shim (8). 5. Install the new adjusting shim, the spring, the sprig seat, the spacer, the injection nozzle, and the re- taining nut. Incorrect (Dripping) (3) If the spray condition is bad, the injection nozzle must be replaced or adjusted. Incorrect (Restrictions in orifice) (2) N6A0029E Refer to “Adjustment”. N6A0856E Notice: Adjust the nozzle in a well ventilated area. Do not inhale oil or spray injected from the nozzle. 6. Clamp the injection nozzle holder in the vise. 7.
Tighten the injection nozzle holder retaining nut to the specified torque. Disassembly Tighten: Injection nozzle holder retaining nut to 34 N m (3.5 kg m / 25 lb ft) 4-1 Injection Nozzle (Two spring nozzle holder) (4HG1-T only) The two-spring nozzle holder has been developed to re- duce NOx (Nitrogen Oxides) and particulates from direct injection diesel engine exhaust. 8. Remove the injection nozzle holder from the vise. Adjusting Shim Availability mm (in) Range 0.5 — 1.5 (0.02 — 0.06) Increment 0.025 (0.001) Total Number of Shims 41