Injection Volume and Governor Performance Diagram Identification Numbers : 101401-7311 [4HF1 Engine] Pre-stroke : No. 1 plunger 4.1 ± 0.05 mm (0.1614 ± 0.0020 in) Injection order : 1 — 3 — 4 — 2 (interval 90 °± 30 ) Plungers are numbered from the Governor side Tappet clearance : Bolt adjustment type : More than 0.3 mm (0.0118 in) for all cylinders. : Shim adjustment type : Manually rotate the camshaft 2 — 3 times and confirm that it rotates smoothly.
Injection Volume Timing Advance Specification Governor Adjustment N6A1655E Adjusting point Pump speed (r.p.m.) Injection volume (cc/ 1000 strokes) Variance (%) Remarks 960 61±1.6 ±4 Basic H 285 16±1.3 ±10.0 A 960 65±1 — Basic B 1,600 (62)±2 — C 500 (63.5)±2 — I 150 (82)+16 −0 — Pump Speed (r.p.m.) 1,000 1,600 or more Degree for Angle of Lead (deg.) 0.5 or less Finish 5±0.5