Isuzu — Isuzu N Series Training Manual

Injection Volume and Governor Performance Diagram Identification Numbers : 104742-1630 [4HF1-2 Engine] Pre-stroke : No. 1 plunger 0.45 ± 0.05 mm (0.0177 ± 0.0020 in) Injection order :

1 — 3 — 4 — 2 (interval 90 °± 30 ) Plungers are numbered from the Governor side Injection volume Timing Advance Specification Governor Adjustment (4HF1-2) N6A1656E Pump speed (rpm) Injection volume (mm3/strokes) Uneven amplitude (mm3/strokes) Oil temperature (°C (°F)) Remarks 500 48.2 ± 4.5 — 48±2 (118±36) 960 60.3±1.0 5.0 50±2 (122±36) Basic 1280 63.9±3.5 — 50±2 (122±36) 1600 61.4±4.5 — 50±2 (122±36) 1925 17.9±3.0 5.5 50±2 (122±36) Basic 300 10.1±2.0 2.0 48±2 (118±36) Basic 150 37.0±10 — 48±2 (118±36) Pump Speed (r.p.m.) 1,100 1,280 1,600 1,800 Degree for Angle of Lead (deg.) 0.7 2.8 6.2 Finish 6.5