Injection Volume and Governor Performance Diagram Identification Numbers : 101401-7452 [4HG1-T Engine] Pre-stroke : No. 1 plunger 3.8 ± 0.05 mm (0.1496 ± 0.0020 in) Injection order : 1 — 3 — 4 — 2 (interval 90 °± 30 ) Plungers are numbered from the Governor side Tappet clearance : Shim adjustment type : Manually rotate the camshaft 2 — 3 times and confirm that it rotates smoothly. : Bolt adjustment type : More than 0.3 mm (0.0118 in) for all cylinders. Injection Volume Timing Advance Specification Adjusting point Rack Posi- tion (mm (in)) Pump Speed (rpm) Injection q’ty (cm3/ 1000strokes) Max var bet. cyl. (%) Fixed Remarks 11.5 (0.4528) 1000 73.5±1.6 ±4 Rack Basic H Approx.
8.9 (0.3504) 315 (Measure)±1.3 ±10 Rack A R1 (11.5 (0.4528)) 1000 73.5±1 — Lever Basic Boost press. kPa (mmHg/ psi) Above 62.0 (465/8.99) B R1 +1.0 (0.0394) 1500 (78.5)±2 — Lever Lever Boost press. kPa (mmHg/ psi) Above 62.0 (465/8.99) C R2 -0.8 (0.0315) 500 (66.5)±2 — Lever Boost press. 0 I — 150 (Measure)±16 — Lever Boost press. 0 Confirm that the timing of is advanced 1°±30′ from A. Pump speed (rpm) Below (N1 + 50) N1 N3 Advance angle (°) Start Below 0.5 Finish 4.0±0.5