Vacuum Pump Disassembly 2. Vane N6A1066E 1. Remove the center plate from the vacuum pump housing. 2. Remove the vacuum pump rotor and the vanes from the housing. Inspection and Repair 1. Vacuum Pump Housing and Center Plate N6A1068E Inspect the vanes for excessive wear and damage. Replace all four vanes if either of these conditions are present. Never replace only one vane. 3. Rotor 1) Inspect the rotor for excessive wear, abrasion, and scoring. Pay particular attention to the internal spline. Replace the rotor if any of these conditions are present. 2) Inspect the generator rotor shaft splines for backlash. Replace the rotor if backlash is present. 4.
Check Valve 1) Carefully force the valve from the “B” side as shown in the illustration. N6A1067E Inspect the vacuum pump housing and the center plate for excessive wear, abrasion, and scoring. If any of these conditions are present, the vacuum pump housing and center plate must be replaced. Inspect the vacuum pump housing inside for wear and damage. If the measured inside diameter is outside the specified range, replace the vacuum pump hous- ing. Vacuum Pump Housing mm (in) Inside Diameter (Reference) Standard 69.5 — 69.6 (2.736 — 2.740) Vane Length (Reference) mm (in) Standard 18.0 (0.709)