Inspection and Repair When abnormal, check the QOS timer, the glow re- lay and the thermo switch. When normal, check the glow plug. Timer 1. Disconnect the connector of the thermo switch. 2. Set the voltage meter in connection as shown the illustration with connector connected. Make the necessary adjustments, repairs, and part re- placements if excessive wear or damage is discovered during inspection. Quick-On-Start II (QOS II) System 1. Disconnect the connector of the thermo switch. N6A1093E N6A1095E 2. Set the voltage meter in connection as shown in the illustration. 3. Turn the key switch to “ON” position without engine turned, and check the following. Glow Plug Relay Location N6A1094E 3.
Turn the key switch to “ON” position without engine turned and check the following items. N6A1096E Specification Measure the glow relay resistance between the terminal (4) and the (5) with a circuit tester. 0 Volts Indicating Time Seconds Standard 18 Glow Indicator Lighting Time Seconds Standard 3.5 Power Source Voltage Indi- Seconds cating Time Standard 18