Isuzu — Isuzu N Series Training Manual

* Equipped with EGR and VSS Location of Sensor and Switch N6A1139E Error Classified Trouble Code Diagnostic Condition Return Condition Back Up Judging Time Mag- netic Vol- ume Timing Harness Open P23 Output TR Monitor When forward normal Timing Advance: MV out- put stop. 0.52 sec GND short +B short P24 Harness Open GND short P45 Engine speed 0, Rack Voltage ≥ 0.3V ≤ 0.57 is detected. When forward normal EVRV: EGR VSV: EGR Quick Cut VSV: VSS R/L: QWS The above outputs Idling position output stop when T/M POS SW out- putted. VSV: ANECON is actu- ated 1.52 sec