Isuzu — Isuzu N Series Training Manual

Resistance value Notice: Resistance value is difference according to the temperature of temperature sensor. Inspection Point Resistance Value Temperature on sensor Reference Connector Pin No. 3 pin Black 1 ←→ 3 ∞ — Thermistor for ENGINE ←→ Thermistor for meter 1 ←→ 2 2.5 (kΩ) 20°C (68°F) Thermistor for ENGINE 247 (Ω) 90°C (194°F) 1 ←→ Body ∞ — Thermistor for ENGINE ←→ Body 2 ←→ 3 ∞ — Thermistor for ENGINE ←→ Thermistor for meter 3 ←→ Body 146.6 (Ω) 60°C (140°F) Thermistor for meter ENGINE 2 ←→ Body ∞ — Thermistor for ECM ←→ Body Step Action Value YES NO 1 Was the “on-board diagnostic (OBD) system check” performed? — Go to Step 2 Go to self diag system check 2 1. Ignition “OFF” 2.

Disconnect the ECT sensor electrical con- nector. 3. Jumper the ECT sensor signal circuit and the ECT sensor ground circuit together at the ECT sensor harness connector. 4. Observe the “Engine cool temp” display on the scan tool. Is the “Engine cool temp” at the specified value? 120°C (248°F) Go to Step 4 Go to Step 3 3 1. Ignition “OFF” 2. Jumper the ECT signal circuit at the ECT sensor harness connector to chassis ground. 3. Observe the “Engine cool temp” display on the scan tool. Is the “Engine cool temp” at the specified value? 120°C (248°F) Go to Step 5 Go to Step 6 4 Check for poor connection at the ECT sensor and replace terminals if necessary. Did any terminals require replacement?

— Go to Step 8 Go to Step 10 5 1. Ignition “OFF”. 2. Disconnect the ECM, and check the ECT sensor ground circuit for an open. 3. If the ECT sensor ground circuit is open, repair it as necessary. Was the ECT sensor ground circuit open? — Go to Step 7 Go to Step 10