Isuzu — Isuzu N Series Training Manual

Inspection 1. Thermosensor (Engine coolant temperature (ECT)) Soak the temperature sensitive part of a ther- mosensor in the water, and while changing the wa- ter temperature, make sure the resistance is changed as the following graph shows: N6A1264E Legend 1. 2 Pin 2. Port Connect battery voltage between VSV connector terminals and make sure of the continuity between the pots. N6A1254E N6A1255E N6A1265E Legend 1. Resistance (k Ω ) 2. ECT ° F ( ° C) Airtight Check Apply negative pressure to the negative pressure input port as illustrated on the left. Although there is leakage, it is no problem if the negative pressure rises to -46.7 kPa (-350 mmHg / -6.77 psi) or more. 2.

Vacuum Switching Valve (VSV) Resistance Check Check the resistance between the VSV connector terminals using a circuit tester. Cold Resistance : 37 — 44 ( Ω ) (for 12 Volt) : 159 — 169 ( Ω ) (for 24 Volt)