Isuzu — Isuzu N Series Training Manual

Inspection Although there is leakage, it is no problem if the negative pressure rises to -46.7 kPa (-350 mmHg / -6.77 psi) or more. Vacuum Switching Valve (VSV) Resistance Check Check the resistance between the VSV connector termi- nals using a circuit tester. Cold Resistance : 37 — 44 ( Ω ) (for 12 Volt) : 159 — 169 ( Ω ) (for 24 Volt) N6A1266E Caution: When measuring resistance with a circuit tester, be careful not to damage or deform the terminals. N6A1264E Working Check Apply powervoltage between the terminals, there is no problem if the negative pressure does not rise when ap- plied to the input port. Legend 1. 2 Pin 2.

Port Connect the battery voltage between VSV connector terminals and make sure of the continuity between the ports. N6A1289E Legend 1. FICD actuator 2. Aneroid compensator actuator 3. Full rod set lever N6A1265E Airtight Check Apply negative pressure to the negative pressure input port as illustrated on the left. 1. Diaphragm is built in the actuator, by which the in- side of the actuator is divided into two, atmospheric room and negative pressure room.