9. Starting Motor 9.1.8 Characteristic test Since the characteristics can be checked roughly by means of a simple no-load test as explained elow. b NOTE: Complete the test quickly since the rating of the starting motor is 30 seconds. (1) No-load test Fix the starting motor on a test bench and connect wiring as shown in Fig.31. When the switch is closed, a current flows in the starting motor, which is rotated at no-load. Measure the current, voltage and number of revolutions then and check if they satisfy the specified characteristics. 155