Komatsu — 9.2.6 Inspection and maintenance

9. Starting Motor 9.2.6 Inspection and maintenance (1) Armature 1) Check the commutator for rough surface. If so, smooth the surface using #500 to #600 emery cloth. If the outside periphery of the commutator has been deflected over 0.2 mm, repair by a lathe. 2) Measure the depth of the insulating material between commutator segments, and correct if it is less than 0.2 mm. 167