Yanmar — Yanmar Electronic Control System Technical Manual for Classic, BY2, 6LY3, 6CX, and SY GEN III Series Engines

6 Interface Modules 6LY3, 6CX Fuel Sender Connections Note: Software revision 2.03 and earlier units do not have a second fuel input or European calibration. The i8320/25 electronics box can handle a single pole fuel sender with a range of 33 to 240 ohms (US standard input signal). The connection is made from the sender output to pin 7 of the J3 connector- plug on the CE425XX Engine harness. This connects with the mating J3 receptacle on the i8320/25 Engine Interface Modules. The connector is a Deutsch DT style connector. For Dual Pole Senders make the ground connection on J4, pin 12. The tank must have a good ground back to the main ground terminal post to operate accurately.

The contact used to make the connection is Deutsch 1062 16-0122. It fits 16 to 18 AWG wire. To insert the new contact, first remove the orange wedge and follow “contact insertion” (see “Section 13 - Deutsch Connectors” in this manual). Note: With software revision 2.05 and higher, the information applies with the following changes and additions: J5-5 no connections, US sender, 33 - 240 ohms. J5-5 connects to J5-12, European sender 10 - 180 Ohms Port or Single Units Fuel Level Input 1 - J3-7: data instance 0 Fuel Level input 2 - J3-4: data instance 2 Starboard Units Fuel Level Input 1 - J3-7: data instance 1 Fuel Level Input 2 - J3-4: data instance 3 J3 Note:

For additional gauge “Instance” information see page 4:25. Water in Fuel Sensor connects to J3, pin 1. the alarm comes on when connecting this pin to the ground. Note: The 6CX530 requires 2.09 software. © 2011 Yanmar Marine International • Rev. 2.0 Yanmar Electronic Control Systems Technical Manual 6:7