7 System Defaults 6CX 6CX series engines Default Settings Single Engine For single engine configuration, the engine interface part number is i8325 (with trolling).
Without Trolling Engine Interface part number i8325 (i8320) **** Idle RPM 650 Split Range Throttle 25% Forward Throttle Curve F5 Reverse Throttle Curve R1 Programmable Shift Delay 7.2 Fixed Shift Delay 0.2 Station Select Protection Off With Trolling Engine Interface part number i8325 Idle RPM 650 Sync Cruise Troll Trans Type ZF Troll Engage RPM* 850 Split Range Throttle 25% Forward Throttle Curve F5 Reverse Throttle Curve R1 Programmable Shift Delay 7.2 Fixed Shift Delay 0.2 Station Select Protection Off Troll Mode** Split Troll Lever Travel 60% Maximum Throttle 40% Troll Throttle Engage Delay*** 0.2 Note: A system reset may be needed for some changes to take effect.
* This sets the maximum RPM where trolling will engage. **Troll Mode functions are not displayed until Troll Mode is selected. ***Shows as “2” on the display. **** Note: All i8320 engine interface modules (numbers in gray) are now supplied as i8325 with trolling. © 2011 Yanmar Marine International • Rev. 2.0 7:6 Yanmar Electronic Control Systems Technical Manual