Yanmar — Yanmar Electronic Control System Technical Manual for Classic, BY2, 6LY3, 6CX, and SY GEN III Series Engines

7 System Defaults sy gen iii Dual Engine For dual engine configuration, the engine interface part number is i8350P/S (no trolling) or i8355P/S (with trolling).

Without Trolling Engine Interface part number i8350P i8350S Idle RPM 600 600 Sync Cruise Cruise Lead Engine* Port Port Split Range Throttle 25% 25% Forward Throttle Curve F8 F8 Reverse Throttle Curve R1 R1 Programmable Shift Delay 9.6 9.6 Fixed Shift Delay 0.2 0.2 Station Select Protection Off Off With Trolling Engine Interface part number i8355P i8355S Idle RPM 600 600 Sync Cruise Cruise Lead Engine* Port Port Troll Trans Type ZF ZF Troll Engage RPM 800 800 Split Range Throttle 25% 25% Forward Throttle Curve F8 F8 Reverse Throttle Curve R1 R1 Programmable Shift Delay 9.6 9.6 Fixed Shift Delay 0.2 0.2 Station Select Protection Off Off Troll Mode** Split Split Troll Lever Travel 60% 60% Maximum Throttle in Troll Mode 40% 40% Troll Throttle Engage Delay 0.2*** 0.2*** Note:

A system reset may be needed for some changes to take effect. *Only shows when Sync is set to Power Train **Troll Mode functions are not displayed until Troll Mode is selected. ***Shows as “2” on the display. © 2011 Yanmar Marine International • Rev. 2.0 Yanmar Electronic Control Systems Technical Manual 7:9