3 i5601E Digital Display calibration-BY2 Unlimited calibration - BY2 Unlimited Shift Actuator (only used with BY2 Unlimited Engines with Stern Drive) This is an Electrical Shift Actuator for use with stern drives that have a mechanical shift lever or cable. CAN Bus signals cause the Acutator to move the shift cable. To Fwd Gear The Actuator Calibration Screen allows user to view the current Actuator Calibration Values. The “ENG SEL” allows changing of Engine for TWIN Eng applications. When the Engine is saved, any previously changed Shift Actuator Settings will cause a prompting of user with a “save settings?” message box.
If answered “Yes” then settings will be saved before switching engine. To Fwd Stroke REV Stroke Send to Unit Selecting this item causes the settings to be saved and become active. This allows verification of operation of the Actuator with the new values. © 2011 Yanmar Marine International • Rev.
2.0 Yanmar Electronic Control Systems Technical Manual 3:39 Menu Item Display choice Value Function SHIFT ACTUATOR - - Enters into Shift Actuator Screen Menu Item Display choice Function To FWD Gear PUSH Defines how cable moves from center of travel to Forward Gear PULL Menu Item Display choice Value Function FWD Stroke 26 mm 26 Defines the length of cable travel from Neutral to Forward Gear Thru Increments at 1 40 mm 40 Menu Item Display choice Value Function REV Stroke 26 mm 26 Defines the length of cable travel from Neutral to Reverse Gear Thru Increments at 1 40 mm 40