Caterpillar — Caterpillar C15 and C18 Engine Operation and Maintenance Manual

Features and Controls Monitoring System 30 SEBU8598 Engine Load – Displays the amount of load on the engine as a percentage. Regen Disable Status – Displays whether the regeneration is manually disabled. DPF Lamp – Displays when a DPF regeneration is needed. Soot Loading – Displays the amount of soot within the DPF as a percentage. Air Inlet Temperature – Displays the temperature of the air entering the engine through the air filter. Intake Manifold Air Temperature – Displays the temperature of the air entering the engine at the intake manifold.

Illustration 28 g02216234 OK/Select button (1) – The OK/Select button is used to confirm the selections that were made with the scroll left/right buttons. Boost Pressure – Displays the amount of pressure of the air entering the intake manifold of the engine. Backlight button (2) – This button is used to turn the backlight of the display on or off. Crankcase Pressure – Displays the amount of pressure within the crankcase of the engine. Scroll left/right button (3) – This button is used to advance through the various screens of the MIPD. Atmospheric Pressure – Displays the amount of atmospheric pressure that the engine is operating in.

Fuel Temp – Displays the temperature of the fuel entering the engine. The MIPD comes with three preset user interfaces. The interfaces are labeled as Operator_1 , Operator_2 , and Operator_3 . Fuel Rate – Displays the amount of fuel being used by the engine. Operator_1 user interface is preset with various engine, aftertreatment, and transmission information over 14 screens. Diagnostic and system information is also included. The information in Operator_1 is displayed via ISO symbols and metric display units. Filtered Fuel Delta Pressure – Displays the pressure across the fuel filter. Low Idle RPM – Displays the low idle speed setpoint in RPM.

Operator_2 user interface is preset with various engine, aftertreatment, and transmission information over 12 screens. Diagnostic and system information is also included. The information is displayed in analog style gauges and English display units. Hi Idle Speed – Displays the high idle speed setpoint in RPM. Desired Speed – Displays the desired engine speed in RPM. Operator_3 user interface is preset with various engine, aftertreatment, and transmission information over 12 screens. Diagnostic and system information is also included. The information is displayed in analog style gauges and English display units. Primary Throttle – Displays the primary throttle position as a percentage.

Secondary Throttle – Displays the secondary throttle position as a percentage. Note: Only use Operator_1 and Operator_2 interfaces on Tier 4 engines. The added aftertreatment parameters in these interfaces are necessary to ensure proper operation. Auxiliary Pressure Sensor 1 – Displays the pressure being measured by the #1 auxiliary sensor if one is being used. Auxiliary Temperature Sensor 1 – Displays the temperature being measured by the #1 auxiliary sensor if one is being used. Parameters Battery Voltage – Displays the battery voltage. Below are a list of all the parameters that are viewable through the three user interfaces used within the MIPD.

Aftertreatment 1 Regeneration Status – Displays the status of the regeneration system as manual or automatic. Engine Speed – Displays the current engine speed in RPM. HEST Lamp – Illuminates when a DPF regeneration is active. Coolant Temperature – Displays the current coolant temperature of the engine.