52 SEBU8598 Maintenance Recommendations Severe Service Application 2. Disconnect the negative battery cable from the battery. If a battery disconnect switch is provided, open the switch. Note: If electrical/electronic components are used as a ground for the welder, or electrical/electronic components are located between the welder ground and the weld, current flow from the welder could severely damage the component. 3. Disconnect the J1/P1 and J2/P2 connectors from the ECM and. Disconnect the wiring from the CEM. Move the harnesses to a position that will not allow the harnesses to contact with any of the ECM, CEM, or pins accidentally. 5.
Protect the wiring harness from welding debris and spatter. 6. Use standard welding practices to weld the materials. i04889860 Severe Service Application SMCS Code: 1000 An engine which operates outside of normal conditions is operating in a severe service application. An engine that operates in a severe service application may need more frequent maintenance intervals in order to maximize the following conditions: Reliability Service life The number of individual applications cause the impossibility of identifying all of the factors which may contribute to severe service operation. Consult your Cat dealer for the unique maintenance that may be necessary for your engine.
An application is a severe service application if any of the following conditions apply: Severe Environmental Factors Illustration 42 g01075639 Use the example above. The current flow from the welder to the ground clamp of the welder will not damage any associated components.
Frequent operation in dirty air Frequent operation at an altitude which is above 1525 m (5000 ft) (1) Engine (2) Welding electrode (3) Keyswitch in the OFF position (4) Battery disconnect switch in the open position (5) Disconnected battery cables (6) Battery (7) Electrical/Electronic component (8) Minimum distance between the component that is being welded and any electrical/electronic component (9) The component that is being welded (10) Current path of the welder (11) Ground clamp for the welder Frequent operation in ambient temperatures which are above 32° C (90° F) Frequent operation in ambient temperatures which are below 0° C (32° F) 4.
Connect the welding ground cable directly to the part that will be welded. Place the ground cable as close as possible to the weld in order to reduce the possibility of welding current damage to bearings, hydraulic components, electrical components, and ground straps.