Caterpillar — Caterpillar C15 and C18 Engine Operation and Maintenance Manual

SEBU8598 61 Maintenance Recommendations Air Tank Moisture and Sediment - Drain 1. Place engine at low idle speed. Ensure all accessories that are normally used for the application are in use, like a fan, or power takeoffs. 1. Open the drain valve that is on the bottom of the air tank. Allow the moisture and sediment to drain. 2. Close the drain valve. 2. Actuate the air shutoff manually. On electrical operator air shutoffs, utilize an applicable power supply or jumper cables from the battery to energize the air shut-off solenoid. Ensure that the solenoid receives only a momentary signal to prevent overheating.

On hydraulic operator air shutoffs, found on some hazardous location units, actuate by pulling the emergency stop handle. 3. Check the air supply pressure. The air starting motor requires a minimum of 620 kPa (90 psi) of air pressure to operate properly. The maximum air pressure must not exceed 1550 kPa (225 psi). The normal air pressure will be 758 to 965 kPa (110 to 140 psi). i02039199 Battery - Recycle 3. Ensure that air shutoff was actuated and that the engine comes to a complete stop. Note: As every application has different parasitic loads and inertia, the duration for the problem to occur cannot be specified.

However, if the engine stumbles or attempts to continue running, these symptoms may be an indication that worn components may need replacement. SMCS Code: 1401-005; 1401-510; 1401-535; 1401- 561; 1401 Always recycle a battery. Never discard a battery. Return used batteries to one of the following locations: If additional help is needed, contact the Dealer Solution Network. A battery supplier An authorized battery collection facility NOTICE Actuating the air shutoff valve may result in oil leak- age past the shaft seal in some cases.

Repeated ac- tuation of the air shutoff valve during loaded operation of the engine can result in mechanical damage to the turbocharger and reduce turbocharger life. A recycling facility i01878164 Battery - Replace SMCS Code: 1401-510 i00847451 Air Tank Moisture and Sediment - Drain (If Equipped) Batteries give off combustible gases which can explode. A spark can cause the combustible gases to ignite. This can result in severe personal injury or death. SMCS Code: 1466-543-M&S Ensure proper ventilation for batteries that are in an enclosure. Follow the proper procedures in or- der to help prevent electrical arcs and/or sparks near batteries. Do not smoke when batteries are serviced.

Moisture and sediment in the air starting system can cause the following conditions: Freezing Corrosion of internal parts Malfunction of the air starting system The battery cables or the batteries should not be removed with the battery cover in place. The bat- tery cover should be removed before any servic- ing is attempted. When opening the drain valve, wear protective gloves, a protective face shield, protective cloth- ing, and protective shoes. Pressurized air could cause debris to be blown and result in personal injury. Removing the battery cables or the batteries with the cover in place may cause a battery explosion resulting in personal injury.