Caterpillar — Caterpillar C15 and C18 Engine Operation and Maintenance Manual

SEBU8598 75 Maintenance Recommendations Engine Air Cleaner Element (Single Element) - Inspect/Clean/Replace i04342930 Engine Air Cleaner Element (Single Element) - Inspect/ Clean/Replace Replace the dirty paper air cleaner elements with clean air cleaner elements. Before installation, thoroughly inspect the air cleaner elements for tears and/or holes in the filter material. Inspect the gasket or the seal of the air cleaner element for damage. Maintain a supply of suitable air cleaner elements for replacement purposes. SMCS Code: 1051; 1054-040; 1054-070; 1054-510 1. Remove the air cleaner cover. Remove the air cleaner element.

NOTICE Never run the engine without an air cleaner element installed. Never run the engine with a damaged air cleaner element. Do not use air cleaner elements with damaged pleats, gaskets or seals. Dirt entering the engine causes premature wear and damage to en- gine components. Air cleaner elements help to pre- vent airborne debris from entering the air inlet. 2. Cover the air inlet to the turbocharger with tape in order to keep dirt out. 3. Clean the inside of the air cleaner cover and body with a clean, dry cloth. 4. Remove the tape for the air inlet to the turbocharger. Install an air cleaner element that is new or cleaned.

NOTICE Never service the air cleaner element with the engine running since this will allow dirt to enter the engine. 5. Install the air cleaner cover. Inspecting Air Cleaner Elements Note: Use of a platform may be necessary to reach the air cleaner element. Clean the air cleaner elements or replace the air cleaner elements when the following conditions occur: Inspect the air cleaner elements before the air filter restriction reaches 2.5 kPa (10 inches of H 2 O). A loss of engine performance may occur when the air filter restriction exceeds this limit. The air cleaner elements must be cleaned or replaced before the air filter restriction exceeds 3.75 kPa (15 inches of H 2 O). Note:

The air filter restriction is measured before the air inlet to the turbocharger compressor. Illustration 54 g00281693 Inspect the clean, dry air cleaner element. Use a 60 watt blue light in a dark room or in a similar facility. Place the blue light in the element. Rotate the element. Inspect the element for tears and/or holes. Inspect the element for light that may show through the filter material. If it is necessary in order to confirm the result, compare the element to a new element that has the same part number. Servicing the Air Cleaner Elements Note: If the air cleaner is not manufactured by Caterpillar, follow the instructions that are provided by the OEM of the air cleaner.

If the air cleaner element becomes plugged, the air can split the material of the air cleaner element. Unfiltered air will drastically accelerate internal engine wear. Your Cat dealer has the proper air cleaner elements for your application. Consult your Caterpillar dealer for the correct air cleaner element. Do not use an element that has any tears and/or holes in the filter material. Do not use an element with damaged pleats, gaskets or seals. Discard damaged elements. Check the precleaner (if equipped) daily for accumulation of dirt and debris. Remove any dirt and debris, as needed.

Storing Air Cleaner Elements If an element that passes inspection will not be used, the element can be stored for future use.